INSULATED "ESP" WALL PANEL


Product Description

Description: This architecturally pleasing panel is ideal for applications that require a flat appearance. Minor striations in the exterior skin provide for a linear appearance in vertical applications while blending with the side joint of the panels. This Tecfoam panel is filled with non CFC polyurethane modified isocyanurate foam achieving R-values up to 40.0.

Dimensions: Nominal 36" coverage; Thickness (T) – 2", 2½", 3", 4" and 5".

Material: Exterior – 24 ga. steel (std). 22 ga. also available.

Interior – 26 ga. steel (std). 24 and 22 ga. also available.

Finish Options: Exterior – Dura-20® (silicone polyester)
Royal K-70® (Kynar 500/Hylar 5000)

Interior – USDA White (standard)
Dura-20 (silicone polyester)

Texture: The exterior and interior skins are embossed only.

Length: The maximum recommended length is 30' 0". Contact IPS for panel length options. IPS offers standard details for stack joint applications for walls over 30' 0" high.

Fasteners: Concealed, 14 ga. steel clip.

Test Data

Test

Purpose

Procedure

Results

Thermal Resistance

Determines insulating
properties of the panels

ASTM C 236
Guarded Hot Box

Good R values for an HCFC Foam System
(see published values for panel type and thickness)

Air Leakage

Measures air leakage
through the panel joints

ASTM E 283
Chamber Method

The leakage rate for panel will not exceed
0.01 CFM/SF at 40 psf pressure differential

Water Penetration

Measures water leakage
through the panel joints

ASTM E 331
Chamber Method

No water penetration at pressure differential
of 50 psf

Strength

Determines the load/span
properties of the roof and wall
panels

ASTM E 72
Chamber Method

Panel load/span and deflection tables
are available

Ignition Properties

Determines ignition temperatures
of the panel core material

ASTM D 1929

Self-ignition temperature is 860 degrees F.
Flash-ignition temperature is 842 degrees F.

Surface Burning

Determines the surface 
burning characteristics of the
core and panels

Underwriters
Laboratories UL 723
(ASTM E 84)

Core Material (5")
Flame Spread 20*, Smoke Developed 400

Finished Panel
2" to 5" Wall Panel

Flame Spread 15*, Smoke Developed 250 - 450

Southwest
Research
Institute
ASTM E 84

 

Finished Panel
2" to 5" Wall Panel

Flame Spread 10*, Smoke Developed 145

Room Fire Test

Evaluates the burning of roof
and wall panels in a room
configuration

Factory Mutual
STD. 4880 (1994)
(UBC 17-5)

Panel is rated
Class 1 to 30 ft. high, 5 in. max. thickness

*The numerical flame spread rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.

Thermal Properties

ESP Wall Panel

Product Code

Thickness

"U" Factor

"R" Factor

ESP 200

2"

.063

16.0

ESP 250

2 1/2"

.050

19.9

ESP 300

3"

.042

23.9

ESP 400

4"

.031

31.9

ESP 500

5"

.025

40.0

Note: Insulation values determined by tests conducted in accordance with ASTM C 236 at a mean temperature of 75 degrees F., winter condition corrected to 15 mph outside and still inside.